Kärcher KIRA B 50 vs LionsBot R5
At a glance
KIRA B 50 scrubs at 550 mm and lists 1.5 m for a U-turn. R5 scrubs at 520 mm with 50 L clean water and 40 L recovery. Measure the R5 turn on site. On either trial, time how far the machine gets before somebody handles water or the battery.
Published specifications
| Specification | KIRA B 50 | R5 |
|---|---|---|
| Scrubbing width · Different published figures | 550 mm[1] | 520 mm[2] |
| Body width · Different published figures | 750 mm[1] | 690 mm[2] |
| Body length · Different published figures | 1100 mm[1] | 690 mm[2] |
| Body height · Different published figures | 1200 mm[1] | 1,125 mm[2] |
| Net weight · Different published figures | 228 kg[1] | 200 kg[2] |
| Charging time · Different published figures | 5.2 h[1] | 3 h 30 min[2] |
| Clean water tank · Different published figures | 55 L[1] | 50 L[2] |
| Recovery tank · Different published figures | 55 L[1] | 40 L[2] |
| Minimum passage | 0.9 m[1] | No figure in the cited record |
| Min. U-turn width | 1.5 m[1] | No figure in the cited record |
| Maximum speed | No figure in the cited record | 1.1 m/s[2] |
| Maximum driving gradeability | 6%[1] | No figure in the cited record |
| Listed runtime | 3.5 h[1] | No figure in the cited record |
| Scrubbing runtime | No figure in the cited record | ≤4 h 20 min[2]Manufacturer maximum runtime. |
| Approximate area per tank fill | ≈1,830 m²[1] | No figure in the cited record |
| Cited cleaning productivity | No figure in the cited record | 1300 m²/h[2] |
| Maximum theoretical cleaning rate | ≤2,365 m²/h[1] | No figure in the cited record |
Manufacturer sources
Which model fits the site?
KIRA B 50
Screen KIRA B 50 against the published turn and the position of the optional dock’s drain.
R5
Screen R5 where its 690 mm body helps at door approaches. Obtain the straight passage and turning requirement for the fitted setup.
Buyer questions
Which width should go on the site drawing?
Mark the narrowest straight passage and the space at the end of the aisle separately. Take the second measurement with the selected brush, squeegee or dust mop fitted. Include the turning approach and any required recovery manoeuvre.
How do I estimate refills per shift?
Meter the water used and recovered on a known area at the specified flow. Divide the usable tank volumes by those measured rates, then use whichever tank reaches its limit first. Include the trip to the drain, rinsing and restart.
What belongs in the dock quote?
Specify the exact station, charging supply, fresh water and drain requirements where applicable. Allocate the installation work and ask for an in-country list of filters, brushes and squeegees with lead times.