Skip to content
Request a quote

Kärcher KIRA B 50 vs LionsBot R5

At a glance

KIRA B 50 scrubs at 550 mm and lists 1.5 m for a U-turn. R5 scrubs at 520 mm with 50 L clean water and 40 L recovery. Measure the R5 turn on site. On either trial, time how far the machine gets before somebody handles water or the battery.

Published specifications

SpecificationKIRA B 50R5
Scrubbing width · Different published figures550 mm[1]520 mm[2]
Body width · Different published figures750 mm[1]690 mm[2]
Body length · Different published figures1100 mm[1]690 mm[2]
Body height · Different published figures1200 mm[1]1,125 mm[2]
Net weight · Different published figures228 kg[1]200 kg[2]
Charging time · Different published figures5.2 h[1]3 h 30 min[2]
Clean water tank · Different published figures55 L[1]50 L[2]
Recovery tank · Different published figures55 L[1]40 L[2]
Minimum passage0.9 m[1]No figure in the cited record
Min. U-turn width1.5 m[1]No figure in the cited record
Maximum speedNo figure in the cited record1.1 m/s[2]
Maximum driving gradeability6%[1]No figure in the cited record
Listed runtime3.5 h[1]No figure in the cited record
Scrubbing runtimeNo figure in the cited record≤4 h 20 min[2]Manufacturer maximum runtime.
Approximate area per tank fill≈1,830 m²[1]No figure in the cited record
Cited cleaning productivityNo figure in the cited record1300 m²/h[2]
Maximum theoretical cleaning rate≤2,365 m²/h[1]No figure in the cited record
Manufacturer sources
  1. Manufacturer model specifications
  2. www.lionsbot.com

Which model fits the site?

KIRA B 50

Screen KIRA B 50 against the published turn and the position of the optional dock’s drain.

R5

Screen R5 where its 690 mm body helps at door approaches. Obtain the straight passage and turning requirement for the fitted setup.

Buyer questions

Which width should go on the site drawing?

Mark the narrowest straight passage and the space at the end of the aisle separately. Take the second measurement with the selected brush, squeegee or dust mop fitted. Include the turning approach and any required recovery manoeuvre.

How do I estimate refills per shift?

Meter the water used and recovered on a known area at the specified flow. Divide the usable tank volumes by those measured rates, then use whichever tank reaches its limit first. Include the trip to the drain, rinsing and restart.

What belongs in the dock quote?

Specify the exact station, charging supply, fresh water and drain requirements where applicable. Allocate the installation work and ask for an in-country list of filters, brushes and squeegees with lead times.