Skip to content
Request a quote

KEENON DINERBOT T10 vs PUDU Robotics BellaBot Pro

At a glance

Both list 40 kg total. T10 specifies 590 mm of straight passage and BellaBot Pro 650 mm, with a 10 kg per-tray limit published by PUDU. Measure the gap with chairs occupied, then check the turn and the actual tray loads during a busy service run.

Published specifications

SpecificationDINERBOT T10BellaBot Pro
Total payload40 kg total load capacity[1]40 kg[2]Across trays
Minimum passage · Different published figures590 mm minimum passage width[1]650 mm[2]
Body width · Different published figures486 mm body width[1]55 cm[2]
Body length · Different published figures555 mm body depth[1]57 cm[2]
Body height · Different published figures1399 mm[1]129 cm[2]
Net weight · Different published figures58 kg[1]55 kg[2]
Maximum speed · Different published figuresMaximum 1.0 m/s[1]0.2–1.2 m/s[2]Adjustable speed
Listed runtime9–12.5 hours battery life[1]11 h[3]Manufacturer-listed under no load.
Charging time · Different published figures5.5 hours from 15% to 100%, robot powered on[1]4.5 h[3]
Payload per trayNo figure in the cited record10 kg[2]Per tray
Maximum working slope5° slope angle[1]No figure in the cited record
Tray lengthNo figure in the cited record410 mm[3]
Tray widthNo figure in the cited record500 mm[3]
Manufacturer sources
  1. Manufacturer model specifications
  2. www.pudurobotics.com
  3. www.pudurobotics.com

Which model fits the site?

DINERBOT T10

Trial T10 where the 590 mm doorway or chair gap brings it onto the shortlist. Ask for fitted tray ratings.

BellaBot Pro

Trial BellaBot Pro if the 650 mm opening is available and the actual orders fit the 10 kg tray limit.

Buyer questions

How do I measure the aisle at dinner service?

From the fixed gap between the tables, subtract how far occupied chairs project into the route on each side. Include menus, bag hooks and a server waiting at the turn. Record the tightest usable width and trial it at service speed.

Can one tray take the whole rated payload?

Use the total and each shelf's limit independently. Include plates, covers and the serving tray in the weight. Request the load table for the installed shelves whenever the spec sheet only gives the total.

How should we trial drinks and soup?

Agree the fill level and container with the kitchen. Use cold equivalents first, then test the approved serving setup. Include a floor joint, the entry to a turn and a normal obstacle stop. Log spills, plate displacement and the speed used.