At a glance
Both list 40 kg total. T10 specifies 590 mm of straight passage and BellaBot Pro 650 mm, with a 10 kg per-tray limit published by PUDU. Measure the gap with chairs occupied, then check the turn and the actual tray loads during a busy service run.
Published specifications
| Specification | DINERBOT T10 | BellaBot Pro |
|---|---|---|
| Total payload | 40 kg total load capacity[1] | 40 kg[2]Across trays |
| Minimum passage · Different published figures | 590 mm minimum passage width[1] | 650 mm[2] |
| Body width · Different published figures | 486 mm body width[1] | 55 cm[2] |
| Body length · Different published figures | 555 mm body depth[1] | 57 cm[2] |
| Body height · Different published figures | 1399 mm[1] | 129 cm[2] |
| Net weight · Different published figures | 58 kg[1] | 55 kg[2] |
| Maximum speed · Different published figures | Maximum 1.0 m/s[1] | 0.2–1.2 m/s[2]Adjustable speed |
| Listed runtime | 9–12.5 hours battery life[1] | 11 h[3]Manufacturer-listed under no load. |
| Charging time · Different published figures | 5.5 hours from 15% to 100%, robot powered on[1] | 4.5 h[3] |
| Payload per tray | No figure in the cited record | 10 kg[2]Per tray |
| Maximum working slope | 5° slope angle[1] | No figure in the cited record |
| Tray length | No figure in the cited record | 410 mm[3] |
| Tray width | No figure in the cited record | 500 mm[3] |
Manufacturer sources
Which model fits the site?
DINERBOT T10
Trial T10 where the 590 mm doorway or chair gap brings it onto the shortlist. Ask for fitted tray ratings.
BellaBot Pro
Trial BellaBot Pro if the 650 mm opening is available and the actual orders fit the 10 kg tray limit.
Buyer questions
How do I measure the aisle at dinner service?
From the fixed gap between the tables, subtract how far occupied chairs project into the route on each side. Include menus, bag hooks and a server waiting at the turn. Record the tightest usable width and trial it at service speed.
Can one tray take the whole rated payload?
Use the total and each shelf's limit independently. Include plates, covers and the serving tray in the weight. Request the load table for the installed shelves whenever the spec sheet only gives the total.
How should we trial drinks and soup?
Agree the fill level and container with the kitchen. Use cold equivalents first, then test the approved serving setup. Include a floor joint, the entry to a turn and a normal obstacle stop. Log spills, plate displacement and the speed used.